Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
11/13/2002 BUILDING - FINAL Approved IVRS - Inspection 0000*
11/07/2002 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) FILL ALL OPEN TRENCHES AND PROVIDE 2 PERCENT GRADE 5' FROM BUILDING 2) ROOF TOP A/C HEATER SPECIFIES MINIMUM FUSE AS 45 AMP ONLY 25 AMP INSTALLED 3) PROTECT ABS PLASTIC VENTS ON ROOF WITH LATEX PAINT 4) EXIT DOORS REQUIRE MINIMUM 36" X DOOR WIDTH STOOPS INSTALLED 5) DETACHED HOUSE REQUIRES SEPARATE GROUND SYSTEM 6) ELECTRIC PANES HAS MORE THAN 6 DISCONNECTS REQUIRES MAIN DISCONNECT 7) NO POWER ON TO TEST ELECTRIC CIRCUITS OUTSIDE 8) NO POWER TO KITCHEN COUNTER GFCI OUTLETS 9) DISHWASHER DRAIN MUST LOOP TO WITHIN 2" OF SINK FLOOD RIM 10) NO POWER TO BATHROOM OUTLETS