Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
08/26/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*/ 1) REINSPECTION
08/16/2002 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) NAIL ALL HORIZONTAL SHEAR JOINTS PER SCHEDULE 4" & 12" 2) STUD CORNERS NAIL 16D'S AT 16" ON CENTER VERTICALLY 3) NEED MECHANICAL CONNECTION END RAFTER OR NAILED TO WALL (WEST GARAGE), ALL END SITUATIONS (USE A H25 4) MISSED HD AT REAR SHEAR 5) HOW ARE PORCH POST TO CORBLE TO BEAM CONNECTED? SEE 12/D1 6) TOE NAIL POP OUTS FRONT TO SHEAR 7) MISSING 4 X 4 POST AT EACH BEAM GARAGE OP3.1 OR FIND PLAN SHOWING GLU LAM UNSUPPORTED AT INTERMEDIATE PT 8) PLAN CALLS FOR BCI 600 IN LIVING ROOM YOU HAVCE 450'S 9) REAR DINNING ROOM ILR. JOIST 450 PLAN CALLS FOR 500'S ACROSS ENTRIRE REAR 10) REMOVE CRICKETS EAST WEST NAIL DIAPHRAM TO LEDGER, CHECK NAILING IN THE FIELD 11) USE RIM JOIST, OR DOUBLE TGI AT GARAGE 1ST TO 2ND FLOOR 12) STRAP AT BAY WINDOW 13) HOLE IN OSB AT FRONT GARAGE ROOF 14) SHEAR WALL P-2 BETWEEN KITCHEN DINNING NO SHEAR TRANSFER TO ROOF DECK