Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/13/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 09/10/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) H2.5 CLIPS REQUIRED 5 EACH 8D NAILS NAILED INTO WEB STIFFNERS ON BOTH SIDES OF TJI JOISTS DO NOT NAIL INTO LAMINATED OF TJI CHORD OR INTO BEAR WEB OF TJI 2) PLANS CALLS FOR HEADER AT MBN NOT OFFSET WALL 3) REQUIRED HEAD ANCHOR BOLTS 4) WALL NOT ANCHORED IN LIVING ROOM TOP PLATE ALSO BATH 5) CLOTHES DRYER MUST EXHAUST OUTSIDE |
| 08/22/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) GARAGE SHEAR WALL 4 MTT28B REQUIRE EPOXY INSTALLED BOLTS NOT WEDGE ANCHORS. YOU MUST PROVIDE SPECIAL INSPECTION REPORT FOR ALL EPOXY SYSTEMS SEE S2 HOLDOWN SCHEDULE 2) H2.5 CLIPS NOT ALLOWED TO BE INSTALLED WITH NAILS HORIZONTAL INTO SIDES OF TJI CHORDS PROVIDE APPROVED DETAIL FOR H2.5 CLIP INSTALLATION FROM TRUSS MANUFACTURER FILL ALL ROUND HOLES WITH NAILS 3) SHEARWALL STUD CUT (REMOVED) FOR DUCT WORK 4) PROVIDE DETAIL FOR INTERIOR BEARING WALL CONNECTION 5) ALL SILL PLATES REQUIRE 2 ANCHOR BOLTS MINIMUM 6) RED HEAD ANCHOR BOLTS LOOSE THROUGHOUT 7) PEX NOT ALLOWED WITHIN 12" OF RECESSED LIGHTS 8) DUCT BOOT CRUSHED AT RETURN AIR 9) LEAK AT KITCHEN WASTE VENT |