Permit: T02CM02711

Parcel: 121120320

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Permit Number - T02CM02711

Inspection Description - MECHANICAL - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
03/25/2003 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection 0000*OK FOR SHEET ROCK.
03/13/2003 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection 0999*
1.) INSULATE BARE METAL ON TAPERED REGISTER BOXES. USE INSULATION ON TWYES NOT TAPED.
2.) CRIMP ON DRYER VENT ELBOWS RESTRICTING SIZE OF DRYER VENT. 4" ROUND VENT PIPE DOES NOT FIT IN A 3 1/2" WALL. RECOMMEND USING 3 X 4 DOWNSPOUT.
3.) REMOVE SCREEN FROM DRYER VENT T-TOPS.
4.) PROVIDE NAIL PLATES ON DRYER VENTS AS NEEDED.
5.) PROVIDE BACKING AROUND CEILING BOXES.
6.) UNIT 15 MISSING RETURN AIR.