Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM02681
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/10/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
| 09/05/2002 | FRAMING | Not ready for Inspection | 1) MINIMUM VENT SIZE FOR TOILET IS 2" 2) NEED 15" CLEAR CENTER OF CLOSET FLANGE TO TUB SIDE, 30" OVERALL SPACE FOR TOILET 3) STUD SPACING AT FRONT DOOR MAXIMUM 24" ON CENTERR 4) NEED TO STIFF LEG UP TO ROOF RAGTYERS FOR SUPPORTING DROP 5) FINISH ALL FRAMING AROUND DUCTS 7) CHECK FURR OUT SPACING 8) NEW BEARING WALL SECURE RAFTERS TOE NAIL AND INSTALL H2.5'S TO EACH RAFTER OF TOP PLATE 9) MAEK SURE BATHROOM OUTLET IS ON IT'S OWN CIRCUIT 10) PUT WATER LINES UNDER PRESSURE | |
| 09/03/2002 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) PARTIAL UNTIL PLUMBING AND MECHANICAL INTERMEDIATE |