Permit: T02CM02674


Addresses:

1021 N WILMOT RD


Inspection Status: Approved

Inspection History: MECHANICAL - HOODS

Permit Number - T02CM02674

Inspection Description - MECHANICAL - HOODS

Inspection Status - Approved

Date Description Inspector Results Comments
12/13/2002 MECHANICAL - HOODS Approved IVRS - Inspection 0000*
12/11/2002 MECHANICAL - HOODS Partial Approval IVRS - Inspection 0000*
11/20/2002 MECHANICAL - HOODS Partial Approval IVRS - Inspection 0000*
1.) PROVIDE MORE BANDING AT TOP SECTION OF GREASE DUCT.
2.) PROVIDE CLEANOUT ACCESS TO GREASE DUCT. SEE MANFACTURERS DETAIL.
3.) HOOD REQUIRES 1/2" ROD FOR HANGING.
4.) PROVIDE AN ACCESS PANEL IN CEILING NEAR HOOD.
11/18/2002 MECHANICAL - HOODS Partial Approval IVRS - Inspection 0000*
1.) ANY EXPOSED WOOD WITHIN 18" OF THE SIDE OF THE HOOD MUST BE COVERED WITH SHEET ROCK.
2.) PROVIDE AN APPROVED ACCESS OPENING FOR CLEAN OUT IN GREASE DUCT AT CHANGE OF DIRECTION. WELDS ON GREASE DUCT ARE OK
OK TO PROCEED W/FIRE WRAP. SEE MANUFACTURERS INSTRUCTIONS FOR PROPER ACCESS OPENING.