Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T02CM02652

Parcel: 136011740


Addresses:

8225 E SUNDEW DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
07/10/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
07/02/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) NAIL OFF BIRD BOARDS THROUGH ROOF SHEATHING 2) STRAP REAR LEFT CORNER TOP PLATES 3) OUTSIDE RAFTERS ON PATIO ARE NOT STRUCTURAL WOOD MEMBERS. ADD STRUCTURAL RAFTERS INSIDE THEM AND A35 AT LEDGER AND H2.5 AT BEAM