Inspection Status: Approved
Inspection History: PLUMBING - ABOVE CEILING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/14/2002 |
PLUMBING - ABOVE CEILING |
|
Approved |
IVRS - Inspection 0000* |
| 09/27/2002 |
PLUMBING - ABOVE CEILING |
|
Not ready for Inspection |
IVRS - Inspection 0000*1.) NOT INSTALLED AS PER APPROVED PLAN PROVIDE APPROVED AS BUILD DRAWING AT TIME OF NEXT INSP. 2.) NO TEST 3.) FULL SIZE CO REQUIRED ON A BRANCH OVER 5' O". 4.) CODE VIOLATION ON TRANSISSION FROM ABS TO CAST IRON. 5.) WHEN MAKING AS OFFSET USE PROPER FITTINGS DO NOT BEND PIPE. 6.) CLEVIS HANGERS REQUIRED 4'0" ON ABS. |