Inspection History Details
Inspection Status: Partial Approval
Inspection History: FRAMING
Permit Number - T02CM02554
Inspection Description - FRAMING
Inspection Status - Partial Approval
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/11/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) PARTIAL ON FRAMING PENDING BEAM AT PENETRATION TO EXISTING | |
08/08/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) TRAP ON LAUNDRY RISER MUST BE BETWEEN 18"-30" BELOW INLET 2) FRAMING WITHELD FOR PLB CORRECTIONS | |
07/31/2003 | FRAMING | Denied | IVRS - Inspection 0160*/ 1) SHOW LP1225 AT FLOOR FRAMING 2) FIRE STOP SOFFITS AND DROPS 3) FRAME AT TRANSITION WALL BEAM NOT COMPLETED 4) SHIM HEADERS 5) PROVIDE PORCH DETAIL 6) PROVIDE U-VALUE 7) GROUND ALL STEEL BOXES 8) PROTECT CONDUCTORS AT SHARP EDGES 9) GROUND MAIN SERVICE-2 RODS AT 6' SEPARATION 10) LAUNDRY VENTING INCORRECT 11) PROVIDE WATER LINE AND WASTE TEST 12) NAIL PLATE WASTE LINES 13) NOTE MECHANICAL NOT COMPLETED |