Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/27/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 09/20/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) REVISE PLAN TO AS BUILT FOR ADDED WALLS IN KITCHEN/DINING ROOM ADDED ELECTRIC IN LIVING ROOM-THROUGHOUT 2) 2 FOOT CEILING HEIGHT CHANGE IN LIVING ROOM HALL-LIVING ROOM REQUIRES SMOKE DETECTOR 3) DWV TEST OK, OK TO DRAIN 4) FIRE BLOCK CHASE/COLUMN IN BEDROOM 5) TUB SHOWER MUST HAVE TEMP/PRESSURE BALANCED ANTI-SCALD VALVE 6) BOND GAS LINE 7) BOND COPPER PLUMBING 8) WATER HEATER "B" VENT REQUIRES 1" CLEARANCE TO WOOD 9) BATHROOM EXHAUST DUCT MUST EXHAUST OUTSIDE 10) FIRE BLOCK FURRED OUT, LAUNDRY WALK 11) OK TO COVER ALL BUT SHOWER VALVE, LAUNDRY PLAN MUST BE REVISED AND APPROVED |
| 09/19/2002 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 09/15/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) LOOSE NUTS AT BOLTS THRU-OUT 2) WATER TEST REQUIRED AT ABS WASTE AND VENT 3) SMOKE ALARM 36" MINIMUM FROM AIR GRILLS |