Permit: T02CM02537

Parcel: 113103000


Addresses:

1827 E SPRING ST

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
09/06/2002 ROOF NAILING Approved IVRS - Inspection 0000*
09/03/2002 ROOF NAILING Denied 1) SOUTHWEST HOLDOWN DAMAGED, BENT, PROVIDE ALTERNATIVE 2) TRUSS DRAWINGS MUST BE APPROVED BY CITY OF TUCSON 3) ALL TRUSSES BUT A04 NOT PROPERLY BRACED OR BEARING 4) 3/4 NOT COMPLIED WITH AT EACH END AND EVERY 25 FEET 6) SHEAR WALLS MUST BE ATTACHED TO ROOF SYSTEM 6) BEDROOM WINDOW SILL CANNOT EXCEED 14" 7) MECHANICAL UNIT IN GUEST HOUSE CANNOT BEAR ON TRUSS WEB 8) PLUMBING AND ELECTRIC NOT READY 9) STOPPED INSPECTION NEXT FAILURE MAY BE CHARGED A REINSPECTION FEE
08/27/2002 ROOF NAILING Denied IVRS - Inspection 0999*/ 1) NO PLANS OR PERMIT ON SITE 2) NO CITY OF TUCSON APPROVED TRUSS DRAWINGS ON SITE 3) MECHANICAL UNIT AND PLATFORM CANNOT BEAR ON TRUSS WEB OR BOTTOM CHORD. TOP CHORD ONLY 4) ALL STRUCTURE BEDROOM? WINDOW SILLS CANNOT BE HIGHER THAN 44" FINISHED ABOVE FLOOR