Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T02CM02498

Parcel: 136031290


Addresses:

8479 E BOWLINE RD

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/31/2002 FRAMING Approved IVRS - Inspection 0000*
07/30/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) FHA STRAP TOP PLATES AT GAS MAIN AND BANG PLATE AT HOME RUNS 2) SECURE GAS LINE AT HOT WATER HEATER AND ABOVE FIREPLACE 3) CHECK ALL STUDS FOR BANG PLATES AT WIRING 4) SHIM HEADERS WHERE NEEDED 5) BLOCK MASTER EQUALIZER DUCT BOOTS 6) SEAL SLAB AT UNUSED H.D. AT PATIOR DOOR 7) TIGHTEN H.D.'S 8) DWV TEST AND WATER PRESSURE OK
07/26/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*