Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/06/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 08/05/2002 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) INSTALL H.D. NUTS/WASHERS 2) LAUNDRY EXHAUST FAN NOT CONNECTED TO ROOF, HOLE IS COVERED 3) RETURN IN HALL CEILING 6" WITHOUT ANY DUCT ATTACHED? FRESH AIR TO ROOF JACK NOT DUCT 4) REAR BATH EXHAUST FAN DAMPER DOESN'T WORK, NEED ROMEX CONNECTOR FOR ELECTRIC CONNECTION, 2ND FAN MISSING DAMPER 5) SHIM INTERIOR BEARING PTS REAR BEDROOM 6) FINISH INSTALLING WINDOWS AND DOORS |
| 08/02/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) FINISH LAUNDRY VENT DUCT INSTALL 2) FINISH NAILING TC CLIPS 3) BLOCK KITCHEN DUCT BOOT 4) TRUSS CLIPS INSTALLED ON WRONG TRUSSES-TC AND H2.5'S |