Permit: T02CM02445

Parcel: 126171750

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
11/14/2002 BUILDING - FINAL Approved IVRS - Inspection 0000*
11/12/2002 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) NEED PROPER HOUSE ADDRESS # ON BLDG 2) CAULK GAS PIPE AT FIREPLACE PENETRATION, MAKE SURE LABEL ON CAULK TUBE SAYS APPROVED FOR FIREPLACE USE! 3) BAD OUTLET NEXT TO FIREPLACE 4) DRYER VENT, PLUGGED AT EYEBROW 5) LOOSE WATER BOND CLAMP HOSE BIB 6) SHIM UNDER PORCH RAFTER AT BEAM (GAP) 7) INSTALL DOOR AT WATER HEATER, REMOVE TAPE BY VENT TO SINGLE WALL 8) RAISE WATER HEATER FLUE 2' ABOVE GABLE ROOF