Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 11/14/2002 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 11/12/2002 |
BUILDING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) NEED PROPER HOUSE ADDRESS # ON BLDG 2) CAULK GAS PIPE AT FIREPLACE PENETRATION, MAKE SURE LABEL ON CAULK TUBE SAYS APPROVED FOR FIREPLACE USE! 3) BAD OUTLET NEXT TO FIREPLACE 4) DRYER VENT, PLUGGED AT EYEBROW 5) LOOSE WATER BOND CLAMP HOSE BIB 6) SHIM UNDER PORCH RAFTER AT BEAM (GAP) 7) INSTALL DOOR AT WATER HEATER, REMOVE TAPE BY VENT TO SINGLE WALL 8) RAISE WATER HEATER FLUE 2' ABOVE GABLE ROOF |