Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/26/2004 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 01/21/2004 |
BUILDING - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) INSTALL COMBUSTION AND RETURN AIR IN FURNACE/WATER HEATER ROOM |
| 01/13/2004 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) 3/8" DIFFERENCE IN HEIGHT ALLOWED MAXIMUM AT STEPS 2) SEAL LID AT APPLIANCE STAND 3) ALL INSULATION NOT INSTALLED 4) HOT AND NEUTRAL REVERSED AT GFCI (EXTERIOR) 5) INSTALL SMOKE DETECTORS PER CODE 6) INSTALL BOND AT FURNACE BOOT 7) PLACE EXPOSED WIRING AT RANGE HOOD IN CONDUIT 8) INSTALL BACK-FLOWS AT EXTERIOR TAPS 9) PAINT PLASTIC ON ROOF 10) INSTALL DRIP LEGS AT APPLIACNES 11) FLUE 2' ABOVE SIDE WALL WITHIN 8' 12) INSTALL SLEEVE AT FLUES THROUGH FIBER GLASS 13) THREE SCREW FLUES 14) CONDENSATE AND TPR CANNOT BE INTERCONNECTED 15) TPR LEAKING 16) INSTALL ANTI-TIP AT RANGE 17) BLOCK OUT ATTIC ACCESS AND CLEAR WIRING, DUCTS AND WATER LINES 18) NOTE: OUTLETS DO NOT MEET CODE |