Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T02CM02424

Parcel: 123072710


Addresses:

2024 E HELEN ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/26/2002 FRAMING Approved IVRS - Inspection 0000*/ 1) RE-INSPECT
11/21/2002 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) CALLED PHONE NUMBER ON MESSAGE, NO ANSWER; LEFT MESSAGE 2) INSTALL FIREPLACE ANCHOR BOLTS, FIREBLOCKING 3) TIGHTEN ALL ANCHOR BOLTS AND HD'S 4) CONNECT TUB DRAIN 5) SUBMIT ARCHITECT APPROVED REVISIONS TO CITY OF TUCSON PLAN CHECK FOR APPROVAL
11/20/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) ARCHITECT TO SUPPLY LETTER, FOR EPOXY BOLTS AND BEAM SIZE AND H3 NOT REQUIRED CHANGES AT PORCHES 2) INSTALL FIREPLACE 3) PLAN CHANGE OK FOR FLEX DUCT 4) H3'S AT INTERIOR WALL 5) INSTALL 2 1/2" DIAMETER A.B. AT GARAGE MAN DOOR AND EAST WALL JOINT B/PLATES 6) TIGHTEN ALL A.B. AND H.D.'S 7) BANG PLATE HALL CLOSET TOP PLATE 8) GAS PRESSURE TEST PARTIAL ALL OK EXCEPT VALVE TO F/PLACE LOG LITER PENETRATION
11/19/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) NO PLANS/PERMIT VISIBLE
11/07/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) REPLACE FIRE BLOCK AT LAUNDRY ROOM, SOUTH EAST BEDROOM CLOSET, GREAT ROOM 2) MASTER TUB NOT CONNECTED TO DRAIN 3) BEAM SCHEDULE NOT PER PLAN AT PATIOS, SEE KEY NOTE #3 FRAMING FOR FRONT ENTRY 4) NUMBERS CIRCLED ON NOTES FOR 10/21002 NOT COMPLETED 5) DWV'S AND WATER LINES TEST PASSED/PARTIAL ON 3035 UNTIL MASTER TUB CONNECTED
10/21/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) INTERIOR BEARING WALL MISSING A2.5 CLIPS AT SILL PLATE 2) ANCHOR BOLTS REQUIRED WITHIN 12" OF SILL PLATE ENDS 3) RED HEAD ANCHOR BOLTS LOOSE 4) HOLDOWN BOLTS LOOSE/MISSING 5) GARAGE SHEAR PANELS NOT INSTALLED 6) FIREPLACE NOT INSTALLED 7) CLOSET RECESSED LIGHT CANNOT BE WITHIN 6" OF SHELF 8) PROVIDE EPOXY SPECIAL INSPECTION REPORT 9) TUB NOT IN MASTER BATH 10) NAIL PROTECT PLUMBING HALL CLOSET 11) DUCT WORK NOT PER PLAN. CALLS FOR METAL MAIN DUCTS FLEX INSTALLED. HAVE PLAN REVISED TO AS BUILT AND APPROVED BY CITY OF TUCSON
10/18/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) ITEMS AT PREVIOUS INSPECTION NOT CORRECTED 2) NO TEST ON DWV SYSTEM 3) FIREPLACE NOT INSTALLED STOPPED INSPECTION MULTIPLE ITEMS NOT COMPLETE
09/17/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*