Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/13/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/06/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) DOUBLE WALL VENT AT WATER HEATER MUST EXTEND TO 6" BELOW CEILING LEVEL 2) COMPLETE WASHER DRAIN 3) USE GLUE TRAP ON WASHER DRAIN OR PROVIDE ACCESS PANEL |
| 12/27/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) WATER HEATER MUST EXTEND THROUGH ROOF 2) CONNECT PLUMBING VENTS AND EXTEND THROUGH ROOF-(KIT) 3) GAS PRESSURE TEST FAILED 4) ROMEX BELOW CEILING FRMING 5) FRAMING WITHELD FOR OTHER INTERMEDIATE INSPECTIONS |
| 12/26/2002 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |