Permit: T02CM02368

Parcel: 141013160


Addresses:

5040 S CIVANO BL


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T02CM02368

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
09/20/2002 FRAMING Approved IVRS - Inspection 0000*
09/13/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) EXTEND GAS TO FIREPLACE 2) MAKEUP SWITCH BOX IN GARAGE 3) INSTALL HTT16'S PER PLAN 4) COMPLETE FIREPLACE INSTALL
09/12/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) ALL ITEMS NOT CORRECTED
09/10/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) FINISH INSTALL OF ANCHOR BOLT AT GARAGE REAR 2) FINISH SWITCH WIRING AT GARAGE PEDESTRIAN DOOR 4) NEED DWV TEST 5) 6 X 14, AT FRONT DOOR-RUNNING NORTHEAST TO SOUTHWEST, HAS INADEQUATE POST AT SOUTH END AND FOR DOUBLE 2 X 12 FURTHER SOUTH 6) FRONT DOOR HEADER REQUIRES 2 TRIMMERS ON EACH SIDE 7) INSTALL FIREPLACE 8) CORRECT VOER NOTCHING OF TRIMMERS AND CRIPPLES AT NORTH WEST WINDOW AND SHIM WHERE NEEDED 9) MISSING CRIPPLE AT FRONT WINDOW 10) BLOCK DUCT BOOT IN SOUTHWEST BEDROOM 11) NEED RED HEAT AT KITCHEN STOVE AREA 12) WATER PRESSURE TEST-OK