Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T02CM02366

Parcel: 129030200


Addresses:

2318 E PARKWAY TE

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
10/31/2003 BUILDING - FINAL Approved IVRS - Inspection 0000*
10/06/2003 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) INSTALL LIGHTS EXTERIOR 2) COMPLETE ITEMS #1, 5, 6, 11, 13, 14 AND 8 FROM PREVIOUS INSPECTION
09/30/2003 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) 3005-NEED VERIFICATION OF GAS PIPING AND TEST 2) PAINT EXPOSED PLUMBING VENTS ON ROOF 3) INSTALL TO ACCESSIBLE CLEANOUT COVER KITCHEN SINK EXTERIOR 4) LABEL CIRCUITS SERVED MAIN ELECTRIC PANEL 5) COMPLETE ROOFING 6) NO EXPOSED BULBS IN CLOSETS 7) WATER HEATER FLUE INCOMPLETE 8) INSTALL FIXTURE ON PANCAKE BOX ABOVE MAIN PANEL EXTERIOR 9) INSTALL HOSE BIB VACUUM BREAKERS 10) REMOVE UNUSED WATER LINES REAR EXTERIOR 11) ELEVATE AND SECURE DISHWASHER DRAIN HOSE 12) CONNECT DISHWASHER ELECTRIC ACCESSIBLE 13) INSTALL LIGHT OR FIXTURE BEDROOM AND LIVING ROOMS 14) SUBMIT ASBUILT MECHANICAL FOR ROOF MOUNTED ALL IN ONE UNIT APPROVAL 15) INSTALL BONDING JUMPER ACCROSS NON-METALIC A.C. BELLOWS ON ROOF 16) SECURE A/C DISCONNECT FROM TURNING PAINT EXPOSED PVC CONDENSATE ON ROOF 17) CANNOT DRAIN CONDENSATE (A/C) INTO VENT PIPE