Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date |
Description |
Inspector |
Results |
Comments |
| 06/07/2002 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Approved |
IVRS - Inspection 0000* |
| 05/20/2002 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999*/ 1) REINFORCING STEEL CANNOT BE IN DIRECT CONTACT WITH SOIL 2) FOOTINGS MUST BE 16" IN WIDTH WITH 2 EACH #4 REBAR PER PAGE 3 OF 4 OF PLAN 3) PAHD HOLDOWNS ARE IN WRONG LOCATION FOR 2'-8" RETURN PANELS ON FRONT OF GARAGE 4) PAHD HOLDOWNS MUST HAVE REINFORCING STEEL ABOVE HOOK |