Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T02CM02362
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/07/2002 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection 0000* | |
05/20/2002 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection 0999*/ 1) REINFORCING STEEL CANNOT BE IN DIRECT CONTACT WITH SOIL 2) FOOTINGS MUST BE 16" IN WIDTH WITH 2 EACH #4 REBAR PER PAGE 3 OF 4 OF PLAN 3) PAHD HOLDOWNS ARE IN WRONG LOCATION FOR 2'-8" RETURN PANELS ON FRONT OF GARAGE 4) PAHD HOLDOWNS MUST HAVE REINFORCING STEEL ABOVE HOOK |