Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T02CM02358
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/14/2002 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000* | |
08/13/2002 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection 0000*2ND FLOOR KITCHEN SINKS AND LAVATIORIES INSTALLED OK. | |
08/12/2002 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection 0000*1.) FOURTH FLOOR KITCHENS AND LAVATORIES OK 2.) THIRD FLOOR KITCHENS AND LAVATIORIES OK | |
08/09/2002 | PLUMBING - FINAL | Not ready for Inspection | ||
08/08/2002 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) I AM NOT ACCEPTING. UNSUPPORTED STRAINED METAL FLEXIBLE WATER CONNECTORS. 2.) ALL DRAINS MUST BE GRAVITY FLOW, I WILL NOT ACCEPT BACKPITCHED WASTE PIPING. 3.) HAVE PLUMBER CHECK ALL WORK OR RISK RE-INSPECTION FEE. | |
08/07/2002 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) DISHWASHER DRAIN HOSE TO BE SECURED AT DRAIN GUARD HEIGHT. 2.) A TRAP ARM MAY ONLY CHANGE DIRECTION 90 WITHOUT ADDING A CLEAR OUT. 3.) CAULK ALL FIXTURES. | |
08/06/2002 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection 0000*NOT READY FOR INSPECTION. |