Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM02339
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/13/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
06/07/2002 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) AT FRONT WALL BOTTOM PLATE NEEDS TO BE MINIMUM 1" OFF CONCRETE SLAB, SHOULD HAVE HAD A SMALL STEM WALL | |
06/06/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) PROVIDE PROPER HEADER FOR ENTRY DOOR 2) 2 2" X 4" ON EDGE WITH JACK STUDS FOR THE HEADER SUPPORT | |
05/31/2002 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) OUTLETS TO BE 6' FROM DOOR 12'-0" ON CENTER THERE AFTER 2) PORCH LIGHT IS IT GOING TO BE REMOVED? ALSO OLD OUTLET 3) PROVIDE 2 X BLOCKS FOR NAILING AT BOTTOM OF SIDING 4) RELOCATE COMBUSTION AND RELIEF DUCTS TO ANOTHER WALL, EXTERIOR 5) AT FRONT WALL BOTTOM PLATE NEEDS TO BE MINIMUM 1" OFF CONCRETE SLAB, SHOULD HAVE HAD A SMALL STEM WALL |