Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 08/12/2002 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 08/08/2002 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0245*FRONT UNIT 1 NO WIRING INTO BATH EXHAUST FANS 2.) FEEDER CABLE CONNECTOR AT PANEL WILL REQUIRE PROPER TERMINATION. 3.) EXHAUST FAN IN LAUNDRY CLOSET NOT CONNECTED WITH ROMEX. 4.) CABLE TO STOVE/OVEN OUT OF WALL CAVITY. 5.) 4 GANG SWITCH BOX NEEDS END SUPPORT. 6.) RECEPTACLE MISSING IN SHORT WALL TO HALL NEAR KITCHEN 7.) SMOKE DETECTORS MUST BE IN HALL AREA NEAR BEDROOMS NOT IN LIVING KIT. CIELINGS. 8.) WHY IS 14-3 W/9 BEING USED FROM PANEL TO 1ST SMOKE DETECTOR REQUIRES ONLY. |