Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 05/31/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 05/30/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) RE-NAIL ALL SW4'S ACCORDING TO PLANS FIELD AND EDGES 4" ON CENTER 2) CHECK TOTAL ROOF AREA 3) BLUE KRAYO MARKS ON FLOOR INDICATE AREA, BUT NOT ALL 3) NOTIFY SUBS NOT TO INSTALL MATL. ON TRUSSES UNTIL AFTER ROOF NAILING INSPECTION HAS PASSED SOME FABRIC IS NOW TO RN |
| 05/29/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) USE CORRECT NAILS FOR T.C. TRUSS CONNECTORS 2) NEED TRUSS SHOP DRAWINGS 3) MISSING TRUSS CLIPS SOUTH WALL 4) CAN'T FIRND EXTERIOR WALL SHEAR TO ROOF CONNECTIONS 5) FINISH SHEAR TRANSFER AT GARAGE 6) REAR OVER HANG PLY NEED SUPPORT AT 24" ON CENTER MINIMUM GRAIN RUNS SAME DIRECTION AS TRUSS |