Permit: T02CM02293

Parcel: 134082980

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
11/18/2002 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection 0000*
11/06/2002 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0245*REMOVE PANEL COVERS FOR THIS INSPECTION. THANKS 1.) REPAIR THE TOP PLATES ABOVE THE HALL WAY 4 GANG SWITCH BOX. DO NOT NAIL DRAW THE TOP PLATES BECAUSE CABLES WILL BE PINCHED TO TIGHTLY.
2.) RELOCATE THE SMOKE DETECTOR TO THE HALL WAY CIELING OR WALL. KEEP 3 FEET AWAY FROM RETURN AIR DUCT REGISTER. 3.) USE SMOOTH 'J' HOOK STRAPS OR OTHER APPROVED STRAPS TO SUPPORT THE SER CABLE IN ATTIC AND AT WALL SPACE DOWN TO THE METER CAN.