Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T02CM02284
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/21/2004 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
06/16/2004 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :*/ 1) RELOCATED 2 ADA PARKING/PROVIDED 3 AT PARALLEL PARKING NEXT TO BLDG (EXCESS SLOPE/GRADE AT 2 RELOCATED) 2) FINAL FOR BLDG IS DEPENDENT ON ELECTRICAL FINAL. STRUCT, EGRESS, CHAO 11 REQUIRE COMPLETE | |
06/04/2004 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
05/10/2004 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :*/ 1) ADA PARKING MAY SLOPE NO MORE THAN 2 PERCENT IN ANY DIRECTION 2) ACCESSIBLE LAVATORIES MAY BE NO MORE THAN 34" MAX ABOVE FLOOR 3) ACCESSIBLE URINALS MAY BE NO MORE THAN 17" ABOVE FLOOR TO RIM 4) FIXTURES (TRASH, TP DISPENSERS ETC.) MAY NOT ENCROACH INTO CLEAR FLOOR SPACE OF TOILETS, SINKS, ETC... 5) REMOVE ACCESSIBILITY SIGNAGE FROM BATHROOM 132 6) PROVIDE FINAL INSPECTION REPORTS FROM OTHER TRADE INSPECTORS. FIRE MARSHALL AND C OF O INSPECTORS |