Permit: T02CM02257

Parcel: 141013930

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T02CM02257

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/06/2003 BUILDING - FINAL Approved IVRS - Inspection 0000*
04/09/2003 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*
04/07/2003 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) ALL FINALS REJECTED, SAME AS LAST INSPECTION, ALL ROOF ITEMS 2) NO HANDRAIL AT STAIRS 3) PAPER LABEL 2 POLE 60/60 TRUSSES MINIMUM CIR. AMPS 52V=35/35 INSTALLED
03/24/2003 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) NEGATIVE PITCH ON CONDENSATE 2) HOLE IN ROOFING AT CONVIENENCE OUTLET 3) LABEL UNIT FOR OVER CURRENT PROTECTION 4) CONNECTION PVC TO SEAL TIGHT 5) CHECK ALL INTERIOR ITEMS FOR LAST INSPECTION
03/20/2003 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) CHECK ROOF BEFORE CALLING IN
02/12/2003 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) INSTALL STAIR RAIL 2) BALCONY GUARD RAIL TO BE 36" HIGH FROM LOWEST HORIZONTAL BAR 3) WATER HEATER NOT CONNECTED 4) FINISH ALL ITEMS ON ROOF FROM LAST INSPECTION
12/30/2002 BUILDING - FINAL Partial Approval IVRS - Inspection 0000*/ 1) 90 DEGREE FITTINGS, CU AND PVC TO BE SOLDERED AND GLUED 2) GFCI RIGHT SIDE OF SINK WON'T TRIP 3) CHECK PLAN WATER HEATER IN BEDROOM AND PORCH CONNECTION AT RAFTERS 4) ON ROOF METAL FRAME NOT SECURED 5) WIRE TO BE IN CONDUIT 6) MARK THE LABEL FOR AMPERAGE 7) FIREPLACE GAS CONNECT