Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/10/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 06/07/2002 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) OK TO DRYWALL-GABLE ENDS OPEN 2) ATTACH EAST GABLE NON STRUCTUAL TRUST TO WALL WITH RED HEADS 32" ON CENTER. SHOOT PINS TO WALL INTO VERTS EVERY OTHER STUD 3) CHECK WITH PLAN EXAMINER 4) INSTALL 1/2 DIAMETER RED HEADS AT EACH VERT, ON NON STRUCTUAL TRUSS, ANCHOR INTO BOND BEAM 5) IF YOU CAN'T FIND BOND BEAM SHEATH WITH 1/2" EDX. ON INSIDE OF TRUSS BOTTOM CHORD TO TOP CHORD |
| 06/06/2002 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000* |
| 06/03/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) PROVIDE CITY OF TUCSON APPROVED TRUSS DRAWINGS 2) CLIP WEST GABLE TO TOP PLATE AT 32" ON CENTER 3) PROVIDE CRIPPLE STUDS UNDER TRUSS NOTCHES FOR LOOK OUTS 4) CROSS BRACE THREE TRUSSES AT EACH END AT RIDGE OR STORAGE WALL EDGE 5) INSTALL TRUSS BRACE RAT RUN ON TRUSSES IF TRUSS DRAWINGS REQUIRE 6) CANNOT APPROVE FRAME UNTIL ELECTRIC COMPLETE |