Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM02229
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/25/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
06/24/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) DRYER VENT WITH 3 90 DEGREE BENDS I ALLOWED A MAXIMUM LENGTH OF 10' TOTAL. YOU HAVER OVER 20' HERE. EITHER REMOVE 2-90 DEGREE OR OTHERWISE BRONG VENT INTO COMPLIANCE WITH CODE. 2) TOP PLATE PLUMBING PENETRATION IN MASTER BEDROOM REQUIRES NAIL PROTECTION | |
06/21/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) DRYER VENT NOT PER CODE 2) NAIL PROTECT ALL STUD AND PLATE PENETRATIONS < 5/8 FROM SURFACE OF MEMBER |