Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/21/2003 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000* PROVIDE FHA STRAPS AS NEEDED |
|
| 07/17/2003 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000* | |
| 07/10/2003 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999* / 1) SEE LAST INSPECTION REQUEST. I WILL NEED REVISED PLANS ON JOB. HAVE PLUMBER REMOVE ? ALLOWING CLOSET FLANGE-WILL REQUIRE AT TEST ON REROUGH OF CLOSET FLANGE-NO CHASE HAS BEEN MADE ON RELIEF LINER ROOF TO CODE SEE PLAN. NOBODY ON JOB. DO NOT COVER. PLEASE PROVIDE NAME AND LICENSE # OF PLUMBING CONTRACTOR OF RECORD WILL REQUIRE PLUMBING CONTRACTOR TO BE ON JOB AT TIME OF NEXT INSPECTION | |
| 07/02/2003 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000*/ 1) PLEASE PROVIDE APPROVED REVISED PLAN ON LOCATION OF WATER SERVICE NOT INSTALLED AS PER PLAN 2) PLEASE SEE PLAN ON RELIEF LINE NOT TO CODE AT THIS TIME 3) ROUGH ON W/C NOT TO CODE SEE CODE FOR PROPER 15" CLARANCE RETEST AND CALL FOR INSPECTION | |
| 06/30/2003 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000*/ 1) PLEASE PROVIDE REVISION AS PER REQUEST 4/25/03-52/23/03 2) DO NOT COVER ANY PLUMBING | |
| 06/26/2003 | PLUMBING - INTERMEDIATE | Partial Approval | 1) ABS DWV THRU ROOF OK WITH EXCEPTIONS CHANGE 1/4 BENDS TO SWEEPS AT KITCHEN SINKS A CONDENSATE DRAIN MAY NOT BE DIRECTLY CONNECTED TO A STAND PIPE RECEPTOR. I NEED TO SEE THESE CHANGES. 2) CLOSET FLANGES OK. OK TO COVER WALLS. 3) TUBS OK. | |
| 06/24/2003 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999*/ 1) I NOTED ON REVISION DATED 6/9/03 BY RWS MODIFYING WATER PIPING-BUT CANNOT LOCATE WHAT THE MODIFICATION ENTAILS ANYWHERE ON THE PLAN 2) SEE NOTE # 3 FROM PREVIOUS INSPECTION | |
| 06/22/2003 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999* 1) PLAN CALLS FOR COPPER UNDER SLAB-PEX IS INSTALLED. PLANSCALLS FOR COPPER ABOVE SLAB -PEX IS INSTALLED 2) REVIEW SECTION ON STAND PIPE RECEPTORS. 3) VENTS MUST RISE VERTICALY TO A POINT NOT LESS THAT 6" ABOVE OVER FLOW OF FIXTURES BEFORE OFFSETTING HORIZONTALLY ALL FITTINGS BELOW THAT TO BE DRAINAGE FITTINGS 4) PEX LEAKS5) NOT A COMPLETE INSPECTION. | |
| 05/23/2003 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000*/ 1) NO TEST 2) NOT TO PLAN 3) NOT READY |