Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 06/18/2003 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000*/ 1) FILL UNUSED OPENINGS IN CANS 2) PLEASE REPAIR TORN CABLE SHEATHING ON SE CABLE 3) OK ROUGH ELECTRIC 10 UNITS |
| 05/23/2003 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/ 1) AN APPROVED CONNECTOR IS NEEDED FOR BOXES 2) PLEASE PROVIDE SWITCH GROUND TAILS AT ROUGH ELECTRIC 3) SERVICE FEEDERS NOT INSTALLED 4) A BOX MAY BE NEEDED AT BATH LIGHT 5) CONDUCTOR TO BE IDENTIFIED AS PER 200-7 6) MAINTAIN FIRE SEPERATION 7) CLASS 1 AND CLASS 2 WIRING NOT ALLOWED IN SAME BOX 8) INSTALL GROUNDS AS PER MANUFACTURERS INSTRUCTIONS ON LABEL |