Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 09/23/2002 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 09/20/2002 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0245*1.) SUPPORT MC WITHIN 12" PER NEC EACH TERMINATION. 2.) LIGHT FIXTURE IN DRIVE THRU CEILING MISSING FLEX FITTING. 3.) DO NOT SUPPORT MC TO EMT CONDUIT, MUST BE SUPPORTED TO STRUCTURE. |
| 09/19/2002 |
ELECTRIC - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*NOTES 1.) OK WALLS INSIDE TELLER OFFICE 2.) MC CABLE MUST BE SUPPORTED WITHIN 12" EACH TERMINATION PER NEC. 3.) INSTALL GROUND RODS BOND TO BLD. STEEL PER 1 LINE DIA. SEE SHEET ON PLAN E3-1. 4.) EXPOSED PVC MUST BE SCH 80. |
| 08/05/2002 |
ELECTRIC - INTERMEDIATE |
|
Partial Approval |
OK SERVICE INSTALL NEED BOND POSTED AND APPROVAL OF OTHER INSPECTORS. SEE FORM. |