Permit: T02CM02200

Parcel: 110065370


Addresses:

2951 N CARDELL CI

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
08/30/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
08/22/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0935*/ 1) 4 EACH DOUBLE 2 X POSTS AT GARAGE MISSING 2) GARAGE SHEAR WALL ANCHOR BOLTS MISSING 3) POST CAPS NOT NAILED 4) HOLDOWNS NOT IN 5) SEVERAL POSTS MISSING ON BEARING SHEARWALL 6) HOUSE WRAPPED WITHOUT APPROVAL-REMOVE 7) HAVE FRAME SUPERINTENDENT VERIFY HOUSE BUILT TO PLAN PRIOR TO NEXT INSPECTION ALL FUTURE FAILURES WILL BE CHARGED RE-INSPECTION FEES 8) TO MANY ITEMS STOPPED INSPECTION, REFEE CHARGED FOR LATH INSTALLATION WITHOUT APPROVAL
08/13/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) NO WATER TEST ON SEWER AND VENT LINES, NO WATER TEST ON SUPPLY LINES 2) UNIT WRAPPED IN FOAM COULD NOT FIND CLIP AND SHEATHING APPROVAL 3) AIR DUCT TO BEDROOM #3 CLOSET NOT BLOCKED ON 3 SIDES
07/26/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) POST BASES AND CAPS NOT INSTALLED 2) 25/S3 NOT COMPLIED WITH 3) GARAGE TRIMMERS NOT CLIPPED 4) 6/DT2 REQUIRES LEDGER BLOCKED AND NAILER 5) CORNER NOT SUPPORTED AT 2ND FLOOR 6) STRAPS AND CLIPS MISSING THROUGHOUT
07/18/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0160*/ 1) HOUSE NOT BUILT PER PLAN SEE ITEMS FROM PERMIT #T02CM02204