Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/23/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 12/18/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) FIREBLOCK ALONG CEILING LINE ABOVE PATIO DOOR 2) EDGE NAILING OF WIRES NOT ALLOWED RESTAPLE OUTSIDE GFCI 3) FIRE BLOCK DROP CEILING AT OLD BATH AND CLOSET 4) ONE SLIDING GLASS DOOR DELETED-REVISE PLAN |
| 12/16/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) MISSING ANCHOR BOLT WEST WALL WITHIN 12" FROM CUT PLATE AND 2 ANCHOR BOLTS RIGHT SIDE OF LAUNDRY ROOM WHERE OLD PIPE IS DISCONNECTED. NO ANCHOR BOLTS AT EAST WALL IN LAUNDRY ROOM 2) CLIPS TO TJI NEED TO BE NAILED TO WEB STIFFENERS 3) SLIDING GLASS DOOR HAS BEEN DENIED 4) ELECTRICAL NOT READY FOR INSPECTION 5) GROUND ALL ELECTRICAL METAL BOXES 6) FIREBLOCK MISSING AT LAUNDRY ROOM AND EAST WALL |