Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/28/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 06/25/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) DWV'S FAILED WATER TEST 2) ROOF NOT LOADED 3) BLOCK ALL MECHANICAL VENTS 3 SIDES 4) REPLACE SILL PLATE FRONT BEDROOM CLOSET 5) AT ELECTRIC RACE WAY DOUBLE TOP PLATE BONDED MORE THAN 50 PERCENT REQUIRE STRAPS 16GAUGE WITH 6, 16D NAILS EACH SIDE 6) SHIM HEADERS AT TRIMMERS 7) INTERIOR WALL AT GREAT ROOM NOT NAILED TO FLOOR 8) TUBS NOT GROUTED 9) CHECK ELECTRICAL WIRE FOR STRIPPED INSULATION FRONT BEDROOM TOP WEST WALL AT STAPLE 10) CHECK ALL INTERIOR WALLS FOR SILL PLATE NAILING |