Permit: T02CM02182

Parcel: 11903279C


Addresses:

721 W 41ST ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/28/2002 FRAMING Approved IVRS - Inspection 0000*
06/25/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) DWV'S FAILED WATER TEST 2) ROOF NOT LOADED 3) BLOCK ALL MECHANICAL VENTS 3 SIDES 4) REPLACE SILL PLATE FRONT BEDROOM CLOSET 5) AT ELECTRIC RACE WAY DOUBLE TOP PLATE BONDED MORE THAN 50 PERCENT REQUIRE STRAPS 16GAUGE WITH 6, 16D NAILS EACH SIDE 6) SHIM HEADERS AT TRIMMERS 7) INTERIOR WALL AT GREAT ROOM NOT NAILED TO FLOOR 8) TUBS NOT GROUTED 9) CHECK ELECTRICAL WIRE FOR STRIPPED INSULATION FRONT BEDROOM TOP WEST WALL AT STAPLE 10) CHECK ALL INTERIOR WALLS FOR SILL PLATE NAILING