Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T02CM02176

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
07/15/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
07/12/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) RESULT-WRITE UP FROM 7/11 INSPECTION NOT ON SITE
07/11/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) THERE ARE 2 PIECES OF ROOF OSB, THAT ONLY COVER 1 BAY, ABOVE THE MASTER BATH AND CLOSET, THAT MUST BE BLOCKED ON 4 SIDES 2) THE FRONT PORCH ROOF LEDGER IS NOT CLIPPED 3) THE 2 EXTERIOR FRONT PORCH RAFTERS ARE NOT STRUCTURAL LUMBER. ADD 2 STRUCTURAL MEMBERS INSIDE OF THEM