Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T02CM02173
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/18/2002 | BUILDING - FINAL | Approved | IVRS - Inspection 0000* | |
11/04/2002 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/ 1) WESTERN ONE COAT STUCCO NOT PAINTED 2) NO ADDRESS ON HOUSE 3) TRIM SEWER CLEANOUTS TO GRADE 4) GARAGE DOOR MISSING LIGHTS 5) ROOF TOP A/C NOT LEVEL 6) WASTE VENT ON ROOF DRILLED TO CONNECT A/C CONDENSATE NOT ALLOWED 7) STAIR HANDRAIL NOT INSTALLED 36" +- 2" ABOVE BULL NOSE 8) BARS BULB LIGHT FIXTURES NOT ALLOWED IN CLOTHES CLOSETS OR BATHROOM 9) DISHWASHER DRAIN MUST LOOP TO WITHIN 2" OF SINK FLOOD RIM OR ADD AIR GAP 10) NEED INSULLATION AND STUCCO INSTALLATION CERTIFICATES |