Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 11/18/2002 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 11/04/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) WESTERN ONE COAT STUCCO NOT PAINTED 2) NO ADDRESS ON HOUSE 3) TRIM SEWER CLEANOUTS TO GRADE 4) GARAGE DOOR MISSING LIGHTS 5) ROOF TOP A/C NOT LEVEL 6) WASTE VENT ON ROOF DRILLED TO CONNECT A/C CONDENSATE NOT ALLOWED 7) STAIR HANDRAIL NOT INSTALLED 36" +- 2" ABOVE BULL NOSE 8) BARS BULB LIGHT FIXTURES NOT ALLOWED IN CLOTHES CLOSETS OR BATHROOM 9) DISHWASHER DRAIN MUST LOOP TO WITHIN 2" OF SINK FLOOD RIM OR ADD AIR GAP 10) NEED INSULLATION AND STUCCO INSTALLATION CERTIFICATES |