Permit: T02CM02173

Parcel: 112021240

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T02CM02173

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
08/20/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
08/13/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) SOUTH SIDE GARAGE FRONT #3 SHEAR PANEL MUST EXTEND FROM HOLDOWN TO HOLDOWN ONE BROKEN 2) GARAGE SOUTH WEST CORNER #1 SHEAR APNEL REQUIRES 1/2" AB WITHIN 12" OF PLATE END 3) EAST 6060 WINDOW RACKED 4) OSB ROOF SHEATHING MUST SPAN 2 BAYS, (3 TRUSSES) REPLACE ALL SHORT PANELS 5) TECO TESTED OSB ROOF SHEATHIN IS DELAMINATING. HAVE A WOOD PRODUCTS ENGINEER PROVIDE A WRITTEN CERTIFICATION MEETING REQUIRED STANDARDS DUT TO EXPOSURE TO WEATHER 6) ROOF SHEATHING NOT SUPPORTED ON ONE EDGE ABOVE BATH AT VAULT