116 W ADAMS ST


Inspection Status: Not ready for Inspection

Inspection History: BUILDING - FINAL

Permit Number - T02CM02159

Inspection Description - BUILDING - FINAL

Inspection Status - Not ready for Inspection

Date Description Inspector Results Comments
11/20/2002 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*
10/25/2002 BUILDING - FINAL Denied IVRS - Inspection 0935*/ 1) MICROWAVE CAN NOT BE ON KITCHEN COUNTER ELECTRIC CIRCUIT 2) HOUSE HAS NO HEATING SYSTEM-REQUIRED SEE PLAN YOU MUST PAY A REINSPECTION FEE PRIOR TO NEXT INSPECTION 3) USED AC NOT ALLOWED ON NEW HOME 4) NOT ROOF GFCI OUTLET
09/11/2002 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) A/C NOT LABELED FOR FUSE REQUIREMENT-MARK PROPER LINE 2) A/C CONDENSATE TRAP AND DRAIN NOT INSTALLED 3) A/C DISCONNECT SECURE CANNOT BE SUPPORTED BY ONE CONDUIT 4) NO ADDRESS ON HOUSE 5) NO MECHANICAL SYSTEM MAINTANCE OUTLET (GFCI) ON ROOF 6) SEWER CLEANOUT BROKE 7) MICROWAVE CIRCUIT CANNOT BE ON KITCHEN COUNTER CIRCUIT 8) DISPOSAL DRAIN MUST HAVE AND AIR GAP OR LOOP TO WITHIN 2" OF SINK FLOOD RIM 9) PRVOIDE STUCCO AND INSULATION INSTALLATION CERTIFICATES
08/16/2002 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) HEATING/COOLING SYSTEMS NOT IN 2) NO ADDRESS ON HOUSE 3) PAINT ALL ABS PLASTIC VENTS ON ROOF 4) FILL OPEN TRENCHES 5) GRADE AT 2 PERCENT AWAY FROM HOUSE FOR 5' 6) INSTALL THREADED CLEANOUT CAPS TRIM TO GRADE 7) OUTSIDE HOSE BIBS REQUIRED ANTI-SIPHON VALVE
08/15/2002 BUILDING - FINAL Partial Approval IVRS - Inspection 0000*/ 1) GFCI IN KITCHEN ON RIGHT SIDE OF SINK DOES NOT TRIP 2) NEED ELECTRIC FINAL WHEN REPAIRED APPROVE BLDG FINAL WHEN DONE