Permit: T02CM02159

Parcel: 11507213B


Addresses:

116 W ADAMS ST


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T02CM02159

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/19/2002 FRAMING Approved IVRS - Inspection 0000*
06/18/2002 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) ELECTRIC OUTLETS REQUIRED WITHIN 6 FEET OF DOOR WAYS AND EVERY 12 FEET THERE AFTER 2 EACH MISSING IN LIVING ROOM 2) WIRES KINKED AT BATHROOM OUTLETS MUST HAVE 5 DIAMETER BEND RADIUS
06/13/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) LOOSE ANCHOR BOLTS THROUGHOUT HOUSE 2) ELECTRICAL BOXES WIRES NOT ROUGHED IN 3) PROTECT ALL ELECTRICAL WIRES WITHIN 1 1/4" FROM EDGE OF STUD 4) WATER HEATER TEMP PRV MUST GO TO DAY LIGHT DRAINING INTO WASHER TAIL PIPE NOT AN APPROVED FITTING, MAY APPEAL TO THE BUILDING OFFICIAL AT DSD CITY OF TUCSON 5) PROVIDE APPROVED TRUSS DRAWING 6) STRAP PATIO BEAM INSIDE AND AD 2 X STUDS 2 EACH 7) 2 X 4 OUTRIGGERS 4' ON CENTER NOT INSTALLED 8) REPLACE KING STUD AT KITCHEN WINDOW
05/31/2002 FRAMING Denied IVRS - Inspection 0925*/ 1) NOT READY UNTIL ALL INTERMEDIATES ARE COMPLETE