Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T02CM02127

Parcel: 141304870

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T02CM02127

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
07/17/2002 FRAMING Approved IVRS - Inspection 0000*
07/15/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) NEED WATER, POTABLE WATER TEST 2) SOFFIT NOT ATTACHED TO TRUSS BOTTOM CHORD LIVING ROOM 3) HALL BATH SHOWER DIVERTER NOT INSTALLED 4) NEED WASTE AND VENT WATER TEST 5) 2 X 4 AT BOTH TUB, SHOWER NOTCHED OR OVER DRILLED, SOUTH BATH 6) LOOSE BOTTOM PLATE REAR PORCH WING WALL NEXT TO DINNING ROOM DOOR 7) HCS TYPE HANGER IN HALLWAY USED P-8 NAILS SHOULD BE 10'S CHECK MANUFACTURER SPECS 8) INSTALL TUB AND CLOSET RING HALL BATH, HOW MANY LAV'S ARE TO BE INSTALLED? 9) OVER SPACE STUD ENTRANCE TO BED H2 10) USE DETAIL 7/SD3 FOR GARAGE FOR GABLE BRACING 11) ADD CROSS BRACE AT INTERMEDIATE POINT (TRUSSES), USE NAILS INSHEAR NOT WITHDRAWL AT THESE BRACES NAIL PER SCHEDULE 12) NEED TRUSS SHOP DRAWINGS ON SITE 13) MORE SUPPORT FOR SOFFIT IN LIVING ROOM 14) GAS TEST HOLDING PRESSURE