Permit: T02CM02052

Parcel: 123121750


Addresses:

1303 E EDISON ST


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T02CM02052

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
11/13/2002 FRAMING Approved IVRS - Inspection 0000*
11/05/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) FIRE BLOCK SOFFIT FOR MECHANICAL 2) PROVIDE GROUND PIG TAILS FOR ALL SWITCHES 3) PROVIDE SMOKE DETECTORS IN BEDROOM AND OFFICE 4) LAV/VANITY WEIR HIGHER THAN VENT OPENING, REVENT 5) BLOCK MECHANICAL BOOTS 3 SIDES 6) BATH FAN MUST EXHAUST OUTSIDE 7) SHOWER VALVES NOT IN 8) HIP TRUSSES REQUIRE HANGERS 9) WATER HEATER T & P CANNOT USE CORRIGATED DRAIN LINE 10) REVISE PLAN FOR ROOF CHANGE, MEASURE ROOF HEIGHT 11'-7" AND GAS 11) DELETE GAS FROM PLAN