Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T02CM02016

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
05/24/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*/ 1) ADD BANG PLATE WHERE INDICATED
05/23/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) STRAP ALL CORNER NOT CABIN TIED 2) AT SHEARWALL RENAIL TO MUCH PENETRATION 3) LOOSE SHEATHING AT ROOF AND BIRD BLOCKS NOT NAILED