Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T02CM02001

Parcel: 107060280


Addresses:

1225 W MIRACLE MILE

Inspection Status: Approved

Inspection History: BUILDING PRE-SLAB

Date Description Inspector Results Comments
04/25/2003 BUILDING PRE-SLAB Approved IVRS - Inspection 0000*
02/28/2003 BUILDING PRE-SLAB Denied IVRS - Inspection 0999*
1.) PLEASE CHECK YOUR PLAN YOU HAVE NOT CAN FORMED TO DETAILS 102,103,104,105, OR 106 PP 54.
2.) I WILL NEED SPECIAL INSPECTION REPORTS FOR EXPOXIED DOWELS IN EXISTING RETAINING WALL.
3.) YOU MAY NOT USE ROCKS AS SUPPORTS FOR REINFORCEMENT. USE CMU "DOBIES" OR LISTED PLASTIC SUPPORTS.
4.) REINFORCEMENT PLACED IN CONCRETE CAST AGAINST EARTH REQUIRES 3" CLEARANCE.
12/13/2002 BUILDING PRE-SLAB Denied IVRS - Inspection 0999*NOT AS PER PLAN. CHANGE TO GARAGE.