Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING PRE-SLAB
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/25/2003 | BUILDING PRE-SLAB | Approved | IVRS - Inspection 0000* | |
| 02/28/2003 | BUILDING PRE-SLAB | Denied | IVRS - Inspection 0999* 1.) PLEASE CHECK YOUR PLAN YOU HAVE NOT CAN FORMED TO DETAILS 102,103,104,105, OR 106 PP 54. 2.) I WILL NEED SPECIAL INSPECTION REPORTS FOR EXPOXIED DOWELS IN EXISTING RETAINING WALL. 3.) YOU MAY NOT USE ROCKS AS SUPPORTS FOR REINFORCEMENT. USE CMU "DOBIES" OR LISTED PLASTIC SUPPORTS. 4.) REINFORCEMENT PLACED IN CONCRETE CAST AGAINST EARTH REQUIRES 3" CLEARANCE. |
|
| 12/13/2002 | BUILDING PRE-SLAB | Denied | IVRS - Inspection 0999*NOT AS PER PLAN. CHANGE TO GARAGE. |