Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T02CM01928

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
05/29/2002 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*1.) CONCEALED FLUSHOMETER INSTALLED AND FRAMED OUT FOR ACCESS. 2.) N/H REPAIR OK 3.) SUPPORT FOR COPPER OK 4.) FHA STRAPS ON WRONG SIDE OF PLATE HOWEVER PLATE IS BOLTED TO FLOOR EACH SIDE OF CUT OK 5.) OK TO COVER WALLS.
05/21/2002 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*1.) HAVE PLUMBER REVIEW GENERAL NOTE #2. FLUSH HANDLE FOR ADA TO BE ON WIDE SIDE OF OPENING. 2.) HAVE PLUMBER REVIEW GENERAL NOTE #5 & 9 ABS USED IN LIEU OF N/H PIPE NOT ACCEPTED 3.) COPPER NOT SUPPORTED IN WALL. 4.) THE VALVE STOP FOR THE FLUSHOMETER IS INSIDE THE WALL NOT ACCEPTED. 5.) NO FHA STRAPS ON BASE PLATE.