Permit: T02CM01923

Parcel: 11918036A


Addresses:

600 W AJO WY


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T02CM01923

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
06/24/2002 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*
06/13/2002 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*1.) WATER TEST DOWN. SOILS AROUND W.C. DRAINAGE FITTING WET. POSSIBLE LEAK? 2.) HORIZONTAL RE-VENT MAY NOT HAVE BACKPITCH CORRECT AND RETEST.
05/23/2002 PLUMBING - ROUGH, SOIL Not ready for Inspection 1.) PLUMBER REMOVE CONCRETE, ONE SIDE ONLY, AND EXPOSE UNDERGROUND FITTINGS FOR WATER CLOSETS AND LAVATORIES. ISOLATE AND TEST DWV PIPING IN BATHROOMS TO TEN FEET. REMOVE DRYWALL FOR ABS AND COPPER INSPECTION IN WALLS. REMOVE DEBRIS IN TRENCH FOR CONNECTION TO EXISTING (OUTSIDE).