Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T02CM01915
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/04/2002 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*1.) PLBG. FINAL IS OK 2.) OK FOR C OF O. | |
05/29/2002 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) H.C. WATER CLOSET MUST HAVE OPEN FRONT SEAT. 2.) H.C. WATER CLOSET HANDLE MUST BE ON OPEN SIDE OF RM (ADA SPECS) 3.) MUST CAULK LAVATORY AND WATER CLOSET 4.) WATER HTR WILL REQUIRE A EXPANSION TANK DUE TO CLOSE SYSTEM BY BACKFLOW PREVENTER. |