Permit: T02CM01903

Parcel: 12306029A

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T02CM01903

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/15/2002 PLUMBING - FINAL Approved 1.) PLBG FINAL IS OK 2.) OK FOR C OF O.
05/09/2002 PLUMBING - FINAL Denied 1.) MUST PROVIDE EXPANSION TANK @ WATER HTR DUE TO CLOSE SYSTEM.
05/02/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) MUST USE A OPEN FRONT SEAT LESS LID ON H.C. WATER CLOSET 2.) MUST EXPOSE C.O. @ SINK ON EAST WALL 3.) MUST CAULK H.C. LAVATORY. 4.) CAN NOT HAVE FLEX LINE IN WATER HTR P & T DRAIN. 5.) HOSE BIB ON SOUTH SIDE REQUIRES A VACUUM BREAKER.