Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/04/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 08/30/2002 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) FIRE BLOCK AT DROP FIREPLACE 2) GAS PRESSURE SET AT 25 PSI 3) TRAINAGE AREA IN KITCHEN REQUIRES FIREBLOCKING 4) ELECTRIC AT ENTERTAINMENT CENTER NOT COMPLETE 5) HEARTH SAFETY STRIP TO BE 1/2 UNDER UNIT 6) FRONT TOILET FLANGE NEED 15" TO CENTER LINE 7) GAS PRESSURE HOLDING |