Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 07/29/2002 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 06/06/2002 |
ELECTRIC - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*ARCH. TO SUBMIT LETTER FOR USE OF ALUM CONDUCTORS FOR SUB-PANEL FEEDER OK INTER, SUBJECT TO RECEIPT OF LETTER FROM ARCH OF CHANGE TO ALUM. FEEDER TO SUB PANEL. |
| 06/05/2002 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0245*1.) PUSH IN GROMMETS NOT ALLOWED AS ROMEX TERMINATION INTO METAL BOXES FOR WALL LIGHTS, ROMEX MUST BE SECURED TO BOX. 370-17 NEC. 2.) USE APPROVED METHOD TO TERMINATE CABLE INTO RANGE RECEPT BOXES, HOLE DRILLED IN PLASTIC BOX NOT APPROVED, 110-3 NEC 110-12. 3.) CAT #5 CABLE NOT AN APPROVED METHOD TO SUPPORT FEEDER ROMEX HOME RUNS INTO PANELS ART 336,110-12,370-17,110-3 NEC. 4.) PLANS INDICATE 150 AMP. PANELS. 5.) ALL CONDUCTORS TO BE COPPER. |